Line Voltage Polarity Error
Line voltage polarity is reversed.
Probable Causes
- Hot and neutral reversed at disconnect or outlet
Diagnostic Steps
- Check outlet polarity
- Correct wiring at disconnect switch
Gas Valve Circuit Fault
Gas valve circuit problem detected.
Probable Causes
- Bad gas valve coil
- Board output failure
- Wiring damage
Diagnostic Steps
- Test gas valve coil resistance
- Check wiring to gas valve
- Test board output voltage
Lockout Retry / Recycle
System in lockout or retry mode due to failed ignition.
Probable Causes
- Ignition failure
- Flame loss during run
Diagnostic Steps
- Check gas supply
- Clean flame sensor
- Test igniter
Pressure Switch Fault
Pressure switch has not closed or has opened during operation.
Probable Causes
- Blocked vent
- Inducer issue
- Hose fault
- Condensate blockage
Diagnostic Steps
- Inspect flue and intake pipes
- Check pressure switch hose
- Test inducer motor amps
- Clear condensate drain
Limit / Rollout Switch Open
High limit or flame rollout switch has opened.
Probable Causes
- Dirty filter
- Airflow restricted
- Flame rollout trip
- Blocked return
Diagnostic Steps
- Replace air filter FIRST
- Check all vents
- Check rollout switches
- Inspect heat exchanger if rollout tripped
Open Fuse / Loss of Flame
Board fuse blown or flame lost during heating cycle.
Probable Causes
- Blown 3A fuse on board
- Short in low voltage circuit
- Flame sensor contaminated
Diagnostic Steps
- Check board fuse
- Inspect low voltage wiring for shorts
- Clean flame sensor
- Check thermostat connections
Flame Without Gas Valve Call
Flame detected when gas valve is off.
Probable Causes
- Leaking gas valve
- Board malfunction
Diagnostic Steps
- SAFETY: Turn off gas immediately
- Test gas valve for leak-through
- Replace gas valve if confirmed
Control Board Self-Test Failure
The control board has failed its internal self-test diagnostic.
Probable Causes
- Control board failure
- Power surge damage
- Component aging
Diagnostic Steps
- Power cycle furnace (wait 30 seconds)
- If persists, replace control board
- Check for proper voltage to board
Normal - No Call for Heat
System is in standby. No thermostat call active.
Diagnostic Steps
- No action needed โ normal standby
Normal - Call for Heat Active
System has received a call for heat and is operating normally.
Diagnostic Steps
- No action needed โ system is running