Goodman Error Codes

14 diagnostic error codes documented

1 Flash critical
Lockout due to Ignition Failure
  1. Check gas supply is on
  2. Test igniter resistance
  3. Clean flame sensor
  4. Test gas valve
1 flash info
Low Heat
  1. No action needed
2 Flash high
Pressure Switch Stuck Open
  1. Check vent termination
  2. Inspect switch hose
  3. Test inducer
  4. Clear drain
2 flash info
High Heat
  1. No action needed
3 Flash high
Pressure Switch Stuck Closed
  1. Test pressure switch
  2. Check inducer relay on board
3 flash critical
Pressure Switch Open
  1. Check flue
  2. Verify inducer
  3. Inspect pressure switch
4 Flash high
Open Limit Switch
  1. Replace filter
  2. Check returns
  3. Test blower motor
4 flash critical
Limit Circuit Open
  1. Replace filter
  2. Check blower
  3. Check ductwork
5 Flash critical
Flame Sensed Without Call for Heat
  1. STOP - gas safety concern
  2. Close gas manually
  3. Test gas valve
5 flash critical
Flame Sensed Out of Sequence
  1. Replace flame sensor
  2. Test gas valve
  3. Check board
6 Flash medium
Line Voltage Polarity Reversed
  1. Check outlet wiring
  2. Correct polarity
6 flash critical
Ignition Lockout
  1. Check igniter
  2. Verify gas supply
  3. Clean flame sensor
7 Flash high
Gas Valve Circuit Failure
  1. Test gas valve coil resistance
  2. Check board output
  3. Inspect wiring
7 flash emergency
Rollout Switch Open
  1. DO NOT BYPASS
  2. Inspect heat exchanger
  3. Check burners