Rheem Error Codes

12 diagnostic error codes documented

1 info
Heating Operational
  1. No action needed
1 Flash critical
Flame Without Gas Valve Energized
  1. STOP - shut off gas
  2. Test gas valve operation
  3. Check flame sensor wiring
2 critical
External Limit Fault
  1. Check limit switches
  2. Check airflow
  3. Reset and observe
2 Flash high
Pressure Switch Stuck Closed
  1. Test pressure switch normally open
  2. Check inducer operation
  3. Replace switch if stuck
3 critical
Pressure Switch Fault
  1. Inspect flue
  2. Check inducer
  3. Test pressure switch
3 Flash high
Pressure Switch Stuck Open
  1. Check flue/intake
  2. Inspect hose to switch
  3. Test inducer amps
  4. Clear condensate
4 warning
Flame Sense Fault
  1. Clean flame sensor
  2. Check grounding
  3. Check gas pressure
4 Flash high
Open High Limit
  1. Replace filter
  2. Check returns
  3. Test blower
  4. Check gas pressure
5 critical
Ignition Fault
  1. Test igniter
  2. Verify gas
  3. Check board
5 Flash critical
Flame Rollout Switch Open
  1. STOP - CO hazard
  2. Inspect heat exchanger
  3. Test CO levels
  4. Check gas pressure
6 Flash critical
Ignition Failure
  1. Verify gas supply
  2. Check igniter resistance (40-200 ohms)
  3. Clean flame sensor
  4. Check grounding
7 Flash critical
Ignition Lockout - Max Retries
  1. Power cycle to clear lockout
  2. Address underlying issue from code 6
  3. Service call needed